The anode height measuring precision pole changing system is installed on the multifunctional crane of the electrolytic aluminum workshop. The system automatically measures the height of the residual pole in the tank, the height of the residual pole itself, the height of the new pole itself, and the height of the new pole should be placed in the tank. Instead of manually completing the replacement of the residual anode. Thus, it improves the precision of the polarity change, improves the safety production capacity, reduces the labor intensity, and realizes the automation and intelligence of the anode pole changing operation.
Technical parameter Anode quantity: Free switching of unipolar/bipolar
Static calibration (simulated pole switching) accuracy :±2mm
Actual polarity change :±3mm
Data transmission method: Wired
Sensing mode : Laser distance measuring sensor (probe), rope displacement sensor, load cell
Mode of operation: Operating instrument / remote control
Save data:9 groups
System contents 1. High temperature laser distance measuring sensor
2. Drawstring displacement sensor.
3. Special instrument for anode height measurement.
4. Special control cabinet for anode height measurement.
5. Inverter motor.
6. Linear motion unit.
7. Air cooling system.
8. Various signal and control cables
Working principles 1. A laser ranging sensor is used to find the bottom of the anode.
2. A drawstring displacement sensor is used to measure the distance.
3. The anode height dedicated meter is the brain of the entire system and is used to process various parts of the signal and various controls.
4. The special control cabinet for anode height measurement is used to control the variable frequency motor.
5. The linear motion unit is used to transport high temperature laser rangefinders to various heights.
6. The air cooling system is used to cool the laser rangefinder.
7. Various signal grid control cables for various signals and control power